Susin

Macro Quater Turn Electrical Actuator

Features
  • Compact and robust construction, light weight providing high output torque(Max 9000Nm).
  • Wide range of torque variation (From min 100Nm to max 9000Nm).
  • Hard anodized aluminum housing inside and outside with external powder coatedagainst severe industrial environment.
  • Enclosure using radial seals & O-rings that provide protection to waterproof IP67(Nema 4 & 6) and optional watertight IP68
  • Mounting base according to ISO5211 standard.
  • Removable drive bushing for easy machining and mounting.
  • Self-locking provided by double worm gearing (no brake required).
  • Auto-declutching manual override handwheel with padlockable auto / manual switchable lever.
  • Reliable Mechanical Torque sensing system providing safe operation in overload condition.
  • Large size window and indicator provides better position indication from a distance.
  • Various Local position control options providing easy commissioning and operation in field.
  • Digitalized control component.

Option Availability

Mechanical
Model Description Remark
EX Explosion proof(Ex d ll B T4) Approved by KTL
EX Watertight (IP68), Temporary submersible 10M Head 100hours
ALS Auxiliary limit switches (Max 2 for each travel end)
ATS Auxiliary torque switches (Max 2 for each travel end) Except for ITQ 0100
EXT Extended travel angle(up to 120o, 135o, 180o, 270o) Except for ITQ with Gear box
SV Variation in torque and operating speed Please consult before ordering
Remote monitoring and control
PK Potentiometer kit (output signal : 0~1 Kohm)
High resolution potentiometer and precisely machined gearing are directly engaged with drive shaft to feedback continuous position of valve
CT Current transmitter (output signal : 4-20mA)
Zero / Span Adjustment
Convertable DIP Switch (4 wire to 2 wire)
RPC/Signal Configuration Remote position controller (by input and output signal)
Input : 4-20mA, 0-10VDC, 2~10VDC, 1~5VDC, 0~5VDC
Output : 4-20mA, 0-10VDC, 2~10VDC, 1~5VDC, 0~5VDC
Auto-calibration Reverse operating direction
Local Control
LP4 for 1 & 3 Phase (ITQ 0160~9000)

Control power : 110/220VAC, Option : 24VDC
Control power : 110/220VAC, Option : 24VDC
Open/Close & Local/Stop/Remote

Local lamp indication
  • Power - White(on), Remote : Blue(on),
  • In case of Close Torque Switch Trip - Yellow(on) + Green(flickering)
  • In case of Open Torque Switch Trip - Yellow(on) + Red(flickering)
  • Full Close - Green(on), Closing - Green(flickering : only at Local Position)
  • Full Open - Red(on), Opening - Red(flickering : only at Local Position)

* Options Available : PK, CT, RPC(Modulating), IP68, Explosion proof

LM4 for 1 & 3 Phase (ITQ 0160~9000)
Including the same functions as LP4
Reversing electric contactors, Transformer
ICM1 for 1 & 3 Phase (Integral Control Module) (ITQ 0160~9000)

Main Power : 3Ph / 220/380/440 VAC
1Ph / 110/220 VAC
Control power : 24VDC, 5VDC

Magnetic selector switches
Open/Close & Local/Stop/Remote
Reversing electric contactors, Transformer, Phase Detector
Local lamp indication
  • Power - White(on), Remote : Blue(on),
  • In case of Close Torque Switch Trip - Yellow(on) + Green(flickering)
  • IIn case of Open Torque Switch Trip - Yellow(on) + Red(flickering) Full Close - Green(on), Closing - Green(flickering : only at Local Position)
  • Full Open - Red(on), Opening - Red(flickering : only at Local Position)
* Options Available : Explosion Proof, IP68
ICM2 for 1 & 3 phase (integral with LCD Display) (ITQ 0160~9000)
Including the same functions as ICM1

Enclosure : Reversing electric contactors, Transformer , Auto-Phase Discriminator, LCD Display
* Options Available : CT, RPC(Modulating), Explosion Proof, IP68, Bus Communication
ICM3 for 1 & 3 phase (integral with LCD Display/IP68 Enclosure)(ITQ 0160~9000)

Enclosure : Reversing electric contactors, Transformer , Auto-Phase Discriminator, LCD Display, IP68, Explosion Proof, RPC(Modulating), Bus Communication 34pins seperate compartment for terminal block
BP for 1 Phase (ITQ 0100~0500)

Rechargeable Battery back up - Fail safe function
When Main power is alive, actuator works as normally.
Once power fails, actuator will move to pre-set fail safe position.
Input power : 110/220VAC, 50/60Hz
Output contacts : open/close/Alarm relay
LED signal indication : 4 LEDs (Full Open/Close, Over Torque and Power)
Rechargeable battery : 2.0AH 27.5VDC(Ni-Cd)